0

ITCertMaster's training product for HP certification HP0-D09 exam includes simulation test and the current examination. On Internet you can also see a few websites to provide you the relevant training, but after compare them with us, you will find that ITCertMaster's training about HP certification HP0-D09 exam not only have more pertinence for the exam and higher quality, but also more comprehensive content.

ITCertMaster's training product for HP certification HP0-D09 exam includes simulation test and the current examination. On Internet you can also see a few websites to provide you the relevant training, but after compare them with us, you will find that ITCertMaster's training about HP certification HP0-D09 exam not only have more pertinence for the exam and higher quality, but also more comprehensive content.

To pass the HP HP0-D09 exam is a dream who are engaged in IT industry. If you want to change the dream into reality, you only need to choose the professional training. ITCertMaster is a professional website that providing IT certification training materials. Select ITCertMaster, it will ensure your success. No matter how high your pursuit of the goal, ITCertMaster will make your dreams become a reality.

Exam Code: HP0-D09
Exam Name: HP (Implementing HP Converged Infrastructure Solutions)
Guaranteed success with practice guides, No help, Full refund!
132 Questions and Answers
Updated: 2013-10-08

In the such a brilliant era of IT industry in the 21st century competition is very fierce. Naturally, HP certification HP0-D09 exam has become a very popular exam in the IT area. More and more people register for the exam and passing the certification exam is also those ambitious IT professionals' dream.

IT exam become more important than ever in today's highly competitive world, these things mean a different future. HP HP0-D09 exam will be a milestone in your career, and may dig into new opportunities, but how do you pass HP HP0-D09 exam? Do not worry, help is at hand, with ITCertMaster you no longer need to be afraid. ITCertMaster HP HP0-D09 exam questions and answers is the pioneer in exam preparation.

HP0-D09 Free Demo Download: http://www.itcertmaster.com/HP0-D09.html

NO.1 .What must be configured or changed in order to enable automated rehosting of virtual or physical
servers in the Converged Infrastructure environment.?
A. resource thresholds
B. storage capacity watermark
C. virtual swap memory setting
D. swap file storage location
Answer: A

HP   HP0-D09 original questions   HP0-D09   HP0-D09 test questions

NO.2 You add new server blades to chassis managed by Matrix OE. What can you use to perform initial
deployment of VMware hypervisor hosts?
A. IO templates
B. IO servers
C. Insight Control deployment jobs
D. VMware vCenter templates
Answer: C

HP exam   HP0-D09   HP0-D09 exam prep   HP0-D09 exam simulations   HP0-D09

NO.3 .You have completed installing a number of Virtual Connect (VC) based enclosure installations and
want to capture the most recent enclosure and VC information of all the enclosures. What is the quickest
way to do this?
A. Connect to the Onboard Administrator GUI and capture an enclosure inventory, then connect to Virtual
Connect Manager (VCM) via SSH and collect a 'show all' output.
B. Use the Virtual Connect Support Utility (VCSU) with the 'collect' option.
C. Use VCSU with the 'healthcheck' option.
D. Connect to the Onboard Administrator GUI and capture an enclosure inventory, then connect to Virtual
Connect Manager (VCM) via Telnet and collect a 'show all' output.
Answer: B

HP   HP0-D09 certification training   HP0-D09 questions

NO.4 .Which elements are required for building a disaster recovery solution using HP Matrix OE, if HP
BladeSystem and HP EVA are already installed? (Select three.)
A. HP Insight Recovery Management
B. HP Application Recovery Manager
C. HP Business Copy EVA
D. HP Replication Solutions Manager EVA
E. HP Continuous Access EVA
Answer: A, D, E

HP   HP0-D09 exam   HP0-D09

NO.5 .What does the Central Management Server (CMS) use to initiate and broker the migration process that
is required for Insight Control server migration capability?
A. FCoE
B. HPoncfg
C. PgAP
D. iSCSI
Answer: D

HP test   HP0-D09   HP0-D09 certification

NO.6 .Which functions does HP SIM provide? (Select three.)
A. continuous device monitoring
B. HP systems software update and tracking
C. server deployment
D. inventory reporting
E. migration of old servers to new ProLiant, maintaining operating system, configuration, and data
Answer: A, B, D

HP pdf   HP0-D09 test answers   HP0-D09 study guide

NO.7 .A feature of HP Insight Control Virtual Machine Management minimizes downtime by performing which
function?
A. relocating virtual machines before hardware failures occur
B. relocating virtual machines after hardware failures occur
C. relocating hosts before hardware failures occur
D. relocating hosts after hardware failures occur
Answer: A

HP exam dumps   HP0-D09 braindump   HP0-D09   HP0-D09 pdf   HP0-D09 certification   HP0-D09 original questions

NO.8 A current multi-enclosure Virtual Connect (VC) domain contains four BladeSystem enclosures cabled
together for a single VC domain. An additional BladeSystem enclosure needs to be added to the
environment.What will provide an optimized and fault tolerant configuration with room for future
expansion?
A. adding the additional BladeSystem enclosure to the current VC domain and configuring in Virtual
Connect Manager
B. creating a secondary VC domain with the new BladeSystem enclosure and configuring in Virtual
Connect SmartStart Manager
C. splitting the current VC domain into two separate VC domains and adding the new BladeSystem
enclosure into one of the newly created VC domains
D. adding the additional BladeSystem enclosure to the current VC domain and upgrading to Virtual
Connect Enterprise Manager to manage more enclosures in the domain
Answer: C

HP   HP0-D09   HP0-D09   HP0-D09 pdf   HP0-D09

NO.9 .Which HP Power Regulator setting allows reduced power consumption with little or no impact to
performance?
A. Static Low Power mode
B. Static High Performance mode
C. Dynamic Power Savings mode
D. OS Control mode
Answer: C

HP   HP0-D09 test   HP0-D09   HP0-D09 demo   HP0-D09 dumps   HP0-D09

NO.10 .Which HP product delivers scale out, excellent performance, and a modular storage infrastructure?
A. HP EVA 6400
B. HP P410i
C. HP P2000 MSA
D. HP X9000
Answer: D

HP test questions   HP0-D09   HP0-D09 test answers   HP0-D09 original questions   HP0-D09

NO.11 .Which tool can you use to configure a shared data store for VMware hypervisor cluster?
A. VMware vCenter server
B. VMware hypervisor host profile
C. IO storage pool entry
D. Insight Control for VMware vCenter server
Answer: A

HP   HP0-D09 exam prep   HP0-D09   HP0-D09   HP0-D09 certification training

NO.12 Which tool is appropriate to use to forecast workload memory utilization for future provisioning?
A. HP Software Operations Orchestration
B. HP Matrix OE Capacity Planning
C. HP Insight Installation Advisor
D. HP System Management Home Page
Answer: B

HP   HP0-D09 braindump   HP0-D09   HP0-D09

NO.13 .Click the Exhibit button.The customer sees that the Simulate button for the Room 44L Chiller 1 failure
rule is disabled in the Insight Control Data Center Power Control screen. What should you do to enable
the simulate function for the Room 44L Chiller 1 failure rule?
A. You should copy this rule to a new rule and click on the Simulate button for the new rule.
B. You should edit the rule and mark the Ready for Use button.
C. A rule with the status Not Ready for Use must be at the bottom of the rule list. Therefore, you must use
the down arrow button to move the rule to the bottom of the list.
D. The rule has been simulated before and failed the simulation. Therefore, you must edit the rule,
remove the errors, and then simulate the rule again.
Answer: B

HP   HP0-D09 certification training   HP0-D09 braindump   HP0-D09 exam dumps   HP0-D09 exam simulations

NO.14 .In a BladeSystem Matrix environment, your logical servers are running low on usable storage capacity.
What can you do on the HP StorageWorks EVA4400 SAN array that was attached to the matrix enclosure?
(Select two.)
A. Add additional disk drives and disk enclosure if needed.
B. Change the disk failure protection level to double on the EVA4400.
C. Group new disk drives into the existing disk group.
D. Increase the storage raw capacity by joining two or more units of EVA4400 with the MPX200 router.
E. Change the vRAID level of the virtual disk from level 5 to level 1.
Answer: A, C

HP   HP0-D09   HP0-D09 answers real questions   HP0-D09 study guide

NO.15 What can enabling "iLO event pass-thru" for event monitoring do?
A. increase workload for the iLO
B. enable iLO event collection by the OS of the server
C. duplicate the events generated for a server
D. enable OA to collect all iLO events in a single log
Answer: C

HP braindump   HP0-D09 test answers   HP0-D09 certification training   HP0-D09   HP0-D09 test answers

NO.16 .An engineer is installing BL460 G7 Server Blades and Virtual Connect FlexFabric modules in a c7000
as part of an HP Converged Infrastructure solution. Which external ports can be used for Fibre Channel
connectivity?
A. the first 2 ports
B. the last 2 ports
C. the first 4 ports
D. the last 4 ports
Answer: C

HP   HP0-D09   HP0-D09 exam prep   HP0-D09 exam simulations

NO.17 .When using Insight Control Performance Management and viewing a server availability report, what
does %Minor indicate?
A. percentage of time that a server is up and available for monitoring
B. percentage of overall performance that might be approaching a bottleneck condition
C. percentage of overall performance that is in a bottleneck condition
D. percentage of overall performance that is satisfactory with no impending or existing bottleneck
condition
Answer: B

HP   HP0-D09 pdf   HP0-D09

NO.18 .Your customer has a Converged Networking solution with an HP Virtual Connect and Physical
Instance enabled network card. The customer asks you to change the vMotion network speed. What
should you do to accomplish this?
A. Change the Required Network Speed within a local VMware Console
B. Change the Required Speed with VMware vSphere client
C. Change the Required Network Speed within Virtual Connect Manager
D. Change the Required Network Speed using Onboard Administrator GUI
Answer: C

HP answers real questions   HP0-D09   HP0-D09 demo   HP0-D09   HP0-D09 test answers

NO.19 .How is Dynamic Power Capping achieved?
A. by disabling cores of a processor when a cap is reached
B. by raising the p-state of a processor when a cap is reached
C. by increasing the clock-cycle of a processor when a cap is reached
D. by lowering the p-state of a processor when a cap is reached
Answer: D

HP braindump   HP0-D09   HP0-D09 exam simulations   HP0-D09 exam simulations   HP0-D09 certification

NO.20 .Which virtualization technique does not need to trap and translate all privileged layer instructions
between the guest OS and the actual server hardware?
A. binary translation
B. paravirtualization
C. hosted OS, application-layer abstraction
D. hardware-assisted virtualization
Answer: B

HP exam prep   HP0-D09   HP0-D09 certification   HP0-D09

ITCertMaster offer the latest MB6-872 Practice Test and high-quality LOT-951 PDF Exam Questions training material. Our CAT-380 VCE testing engine and 1Z0-597 dumps can help you pass the real exam. High-quality 700-101 Exam Questions & Answers can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.

Article Link: http://www.itcertmaster.com/HP0-D09.html

Post a Comment

 
Top