Through continuous development and growth of the IT industry in the past few years, HP0-841 exam has become a milestone in the HP exam, it can help you to become a IT professional. There are hundreds of online resources to provide the HP HP0-841 questions. Why do most people to choose ITCertMaster? Because ITCertMaster has a huge IT elite team, In order to ensure you accessibility through the HP HP0-841 certification exam, they focus on the study of HP HP0-841 exam. ITCertMaster ensure that the first time you try to obtain certification of HP HP0-841 exam. ITCertMaster will stand with you, with you through thick and thin.
ITCertMaster's product is prepared for people who participate in the HP certification HP0-841 exam. ITCertMaster's training materials include not only HP certification HP0-841 exam training materials which can consolidate your expertise, but also high degree of accuracy of practice questions and answers about HP certification HP0-841 exam. ITCertMaster can guarantee you passe the HP certification HP0-841 exam with high score the even if you are the first time to participate in this exam.
Through the feedback of many examinees who have used ITCertMaster's training program to pass some IT certification exams, it proves that using ITCertMaster's products to pass IT certification exams is very easy. Recently, ITCertMaster has developed the newest training solutions about the popular HP certification HP0-841 exam, including some pertinent simulation tests that will help you consolidate related knowledge and let you be well ready for HP certification HP0-841 exam.
ITCertMaster is website that can take you access to the road of success. ITCertMaster can provide the quickly passing HP certification HP0-841 exam training materials for you, which enable you to grasp the knowledge of the certification exam within a short period of time, and pass HP certification HP0-841 exam for only one-time.
ITCertMaster's training product for HP certification HP0-841 exam includes simulation test and the current examination. On Internet you can also see a few websites to provide you the relevant training, but after compare them with us, you will find that ITCertMaster's training about HP certification HP0-841 exam not only have more pertinence for the exam and higher quality, but also more comprehensive content.
When you try our part of HP certification HP0-841 exam practice questions and answers, you can make a choice to our ITCertMaster. We will be 100% providing you convenience and guarantee. Remember that making you 100% pass HP certification HP0-841 exam is ITCertMaster.
Exam Code: HP0-841
Exam Name: HP (Designing and Implementing HP SAN Solutions)
Guaranteed success with practice guides, No help, Full refund!
187 Questions and Answers
Updated: 2013-09-27
ITCertMaster's practice questions and answers about the HP certification HP0-841 exam is developed by our expert team's wealth of knowledge and experience, and can fully meet the demand of HP certification HP0-841 exam's candidates. From related websites or books, you might also see some of the training materials, but ITCertMaster's information about HP certification HP0-841 exam is the most comprehensive, and can give you the best protection. Candidates who participate in the HP certification HP0-841 exam should select exam practice questions and answers of ITCertMaster, because ITCertMaster is the best choice for you.
HP0-841 Free Demo Download: http://www.itcertmaster.com/HP0-841.html
NO.1 What are the three types of fabric zoning on B-series switches? (Choose three.)
A.static zoning
B.software zoning
C.hardware zoning
D.mixmode zoning
E.QuickLoop zoning
Correct:B C D
HP HP0-841 pdf HP0-841
NO.2 What is the maximum distance per cable segment using 9/125 micron single-mode cable and
long wavelength 2 Gb SFPs?
A.1 km
B.5 km
C.10 km
D.35 km
E.100 km
Correct:C
HP HP0-841 pdf HP0-841
NO.3 Which three operating systems are supported in an HP heterogeneous SAN? (Choose three.)
A.HP NSK
B.IBM AIX
C.IBM OS400
D.Tru64 UNIX
E.Microsoft Windows 2003 Server
Correct:B D E
HP HP0-841 pdf HP0-841
NO.4 What is a Fibre Channel fabric?
A.one or more switches connected together, sharing the same name and routing table
B.two or more switches connected together, sharing the same name and routing table
C.one or more switches connected together, each having its own independent name and routing table
D.two or more switches connected together, each having its own independent name and routing table
Correct:A
HP HP0-841 pdf HP0-841
NO.5 Which three infrastructure components are supported from multiple vendors in an HP Open
heterogenous SAN? (Choose three.)
A.hubs
B.switches
C.ATM gateways
D.storage systems
E.operating systems
Correct:B D E
HP HP0-841 pdf HP0-841
NO.6 What is throughput?
A.the number of requests processed per second
B.the number of I/O requests satisfied per unit of time
C.the amount of time a device needs to process a request
D.the time a device takes to process a request from issuance to completion
Correct:B
HP HP0-841 pdf HP0-841
NO.7 In a single fabric, when multiple paths exist between a host and its storage, which statement is
true?
A.The result could be an unstable fabric.
B.Load sharing is automatically set to static.
C.The FSPF protocol determines best route.
D.The path used is determined by port priority.
Correct:C
HP HP0-841 pdf HP0-841
NO.8 What is the internal M-series switch latency of a HP Fibre Channel switch?
A.between 1us and 2us maximum
B.3us
C.5us
D.33us
E.650us
Correct:A
HP HP0-841 pdf HP0-841
NO.9 A company is running an application that is READ intensive. They are more concerned with
effective READ performance than WRITE performance. They have a limited number of disks so
they need to minimize RAID overhead. What type of RAID should they use?
A.RAID 0
B.RAID 1
C.RAID 1+0
D.RAID 5
Correct:D
HP HP0-841 pdf HP0-841
NO.10 Which statement applies to trunking on B-Series switches?
A.Oversubsciption is impossible with trunking.
B.If one ISL of a trunk fails, the whole trunk fails.
C.Trunking increases the availability because an I/O is not interrupted, even if the master ISL of a trunk
fails.
D.Trunking is more effecient than individual ISLs because it is less probable that congestion will be
experienced.
Correct:D
HP HP0-841 pdf HP0-841
NO.11 What characteristic has the greatest impact on disk performance?
A.bus type
B.drive latency
C.I/O transfer size
D.upgrade from a 1Gb/s HBA to a 2Gb/s HBA
Correct:B
HP HP0-841 pdf HP0-841
NO.12 What are HP SAN management strategies? (Choose two.)
A.automated policy based management
B.policy based backup using the storage management appliance
C.automatic performance optimization using sophisticated high performance management agents
D.storage virtualization using in-band management functionality of the storage management appliance
E.simplified, centralized storage management using standardized web based GUIs residing on a storage
management appliance
Correct:A E
HP HP0-841 pdf HP0-841
NO.13 Which software module of HP OpenView Storage Area Manager (SAM) can you use to control
the access of a managed host to a managed storage device?
A.Storage Builder
B.Storage Allocater
C.Storage Accountant
D.Storage Node Manager
Correct:B
HP HP0-841 pdf HP0-841
NO.14 What is the correct statement about zoning in an interoperable fabric?
A.WWPN zoning is the only allowed method.
B.A mixture of domain ID, port number and WWPN zoning is allowed.
C.Domain ID and port number zoning are the only allowed methods.
D.Zoning is not allowed. The only way to segment a fabric is using the VSAN technology of C-Series
switches.
Correct:A
HP HP0-841 pdf HP0-841
NO.15 In Web Tools, which is a valid switch state?
A.down
B.marginal
C.segmented
D.reconfiguring
Correct:A
HP HP0-841 pdf HP0-841
NO.16 What can you do to minimize communication delays between a host and its storage subsystem?
A.cross couple multiple ISLs
B.ensure there is at least one switch hop
C.connect the two devices to the same switch
D.configure a maximum of four active host ports per ISL
Correct:C
HP HP0-841 pdf HP0-841
NO.17 Which HP SAN Management tool is a highly scalable, Java-based application that manages
multiple B-Series switches and fabrics in real-time?
A.HP StorageWorks Fabric Manager
B.Management Appliance Software v2.1
C.HP OpenView Storage Node Manager
D.HP StorageWorks High Availability Fabric Manager (HAFM)
E.HP OpenView Storage Management Appliance III and HP OpenView Storage Management Appliance
software v2.1
Correct:A
HP HP0-841 pdf HP0-841
NO.18 Three LUNs, sda, sdb and sdc, are connected to a Linux server. You shutdown the server and
physically remove sdb. What happens after the server reboots?
A.The LUNs sda and sdc are accessible, LUN sdb is not listed in the device scan.
B.The LUN sda is accessible, LUN sdc is now sdb and accessible using this name.
C.The LUNs sda and sdc are accessible, LUN sdb is listed as offline in the device scan.
D.The LUNs sda and sdc are accessible, LUN sdb is renamed into sdvb simulating a virtual device.
Correct:B
HP HP0-841 pdf HP0-841
NO.19 The sum of the wait time (in queues) and the service time is _____.
A.data rate
B.request rate
C.response time
D.utilization time
Correct:C
HP HP0-841 pdf HP0-841
NO.20 In the SAN configuration, assume a goal of redundancy for everything. How many Storage
Management Appliances are needed?
A.1
B.2
C.4
D.6
Correct:B
HP HP0-841 pdf HP0-841
ITCertMaster offer the latest 98-372 Practice Test and high-quality VCP510PSE PDF Exam Questions training material. Our EX0-101 VCE testing engine and C_TSCM62_65 dumps can help you pass the real exam. High-quality CUR-009 Exam Questions & Answers can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertmaster.com/HP0-841.html
Post a Comment